Design Features
AC Inputs
*  Two separate AC inputs – one for 
    grid (priority #1), one for generator 
    (priority #2), connect simultaneously, 
    no need to reconfigure when different 
    power sources are available.
*  Generator Input is specifically designed 
    to have more tolerance for wave 
    form distortion, prevents 
    unnecessary “rejection of AC input 
    and switch to inverter” by 
    tolerating distorted wave forms that can 
    be produced by gritty generators
*  Each AC input is programmable for 
    voltage and frequency. User determines 
    what the min and max thresholds are 
    to switch from Grid or Generator 
    to Inverter.
*  Generator start can be initiated by 
    “Status Relay” contact, can be 
    programmed to activate when grid is lost.
Solar Input
*  Connect a solar charge controller directly 
    to the EVO TM though the Battery 
    Charger external DC Input, seamlessly
    integrates solar charging into the 
    EVO’s power system.
*  ONLINE Mode can be used to 
    prioritize Batteries / Inverter over the 
    grid, ideal for those wishing to 
    operate primarily on solar power (when 
    the grid is available, but might be costly).
Battery Charger
*  3 or 4 stage charging with 
    Equalization (must be manually initiated). 
*  Adaptive algorithm is used during Bulk 
    to assess the condition of the battery. 
*  Subsequent stages are then based on 
    the condition of the battery rather than 
    pre-set time periods for Absorption 
    and Float. Prevents unnecessary 
    charging, extends the life of batteries.
*  Programmable – set battery 
    voltage thresholds to initiate charging.
Transfer Switch
*  Zero transfer time when switching 
    from Inverter to Grid. When grid comes 
    on, the inverter synchronizes with the 
    wave form and then transfers instantly 
    at zero crossing.
*  <16ms transfer when going from Grid 
    to Inverter. When grid is lost, the 
    transfer relay switches to inverter at 
    the correct place in the wave form, 
    the transfer takes less than 16ms.
Surge Capacity (Power Boost)
*  The EVO TM has 3X surge power
*  Additionally, the EVO TM has large 
    power overload allowances available 
    for long periods of time. Increased 
    inverter capacity means you can size 
    your inverter smaller to handle heavy 
    surge loads, reducing costs.
State-of-the-Art Technology
*  The EVO TM operates at 165 
    million instructions per second 
    producing lightning fast load and 
    response times
*  The EVO TM is practically indestructible. 
    It has “Bullet-Proof Intelligence” in the 
    form of 9 physical points of 
    protection monitoring being scanned up 
    to 10,000 times per second for 
    adverse conditions. The EVO TM will 
    detect fault conditions and initiate a 
    healthy shutdown before any 
    product damage can be done.
*  The EVO-RC remote control 
    (sold separately) can be used to 
    capture detailed EVO TM 
    performance data. Records all 
    detected faults and the conditions 
    leading up to them. 
*  Data is stored on a removable 
    16GB SD Card (in the remote). Use 
    data to analyze trends for more 
    efficient use of system resources
*  The EVO TM uses five temperature 
    sensors placed throughout the unit 
    to determine operation of 2 
    speed controlled cooling fans. 
    Reduces unnecessary fan noise 
    and energy consumption by only 
    running when and where the fans 
    are needed.tails.)